| Property |
Method |
SI Unit |
SI Value |
English Unit |
English Value |
| Density |
ASTM D-792 |
kg/m3 |
944 |
lbs/ft3 |
58.9 |
| Yield Point |
ASTM D-638 |
MPa |
22.4 |
psi |
3250 |
| Elongation at Yield |
ASTM D-638 |
% |
12 |
% |
12 |
| Tensile Break |
ASTM D-638 |
MPa |
38.6 |
psi |
5600 |
| Elongated at Break |
ASTM D-638 |
% |
330 |
% |
330 |
| Tensile Modulus |
ASTM D-638 |
MPa |
1075 |
psi |
155900 |
| Flexural Modulus |
ASTM D-790 |
MPa |
744 |
psi |
107900 |
| Izod Impact |
ASTM D-256A |
J/m |
No Break |
ft-lbs/in |
No Break |
| Sand Wheel Wear |
ASTM G-65 |
T-1000=100 |
95 |
T-1000=100 |
95 |
| Hardness |
ASTM D-2240 |
Shore D |
69 |
Shore D |
69 |
| Static Friction |
ASTM D-1894 |
Unitless |
0.17 |
Unitless |
0.17 |
| Dynamic Friction |
ASTM D-1894 |
Unitless |
0.14 |
Unitless |
0.14 |
| Coefficient of Thermal Exp. |
ASTM D-696 |
°C-1 |
0.00018 |
°F-1 |
0.00011 |
| Melt Point |
ASTM D-3417 |
°C |
137-143 |
°F |
278-289 |
| Compressive Modulus |
ASTM D-695 |
MPa |
480.2 |
psi |
69650 |
| Compression Deformation |
ASTM D-621 |
% at 454.5 kg |
6-8 |
% at 1000 psi |
6-8 |
| Volume Resistivity |
ASTM D-257 |
Ohm-cm |
>1015 |
Ohm-cm |
>1015 |
| Surface Resistivity |
ASTM D-257 |
Ohm |
>1015 |
Ohm |
>1015 |
| Water Absorption |
ASTM D-570 |
% |
nil |
% |
nil |
|
- Material Safety Data Sheets (MSDS) Available on Request
* Values are averages and are not specifications.
** ASTM test methods are under current procedures.
IMPORTANT: Most plastics will ignite and sustain flame under certain conditions.
Caution is urged where any material may be exposed to open flame or heat-generating
equipment Use Material Safety Data Sheets to determine auto-ignition and flashpoint
temperatures of materials, or consult Quadrant, Fort Wayne, Indiana if
additional information
is needed. The information contained herein is believed to be reliable, but no
representations, guarantees or warranties of any kind are made as to its accuracy,
suitability
for particular applications or the results to be obtained therefrom. The information
is based on laboratory work with small-scale equipment and does not necessarily
indicate end product
performance. Because of the variations in methods, conditions and equipment used
commercially in processing these materials, no warranties or guarantees are made
as to the suitability of
the products for the applications disclosed. Full-scale testing and end product
performance are the responsibility of the user. Quadrant, Inc. shall not
be liable and the
customer assumes all risk and
liability of any use or handling of any material beyond Quadrant's direct
control. THE SELLER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
Nothing contained herein is to be considered as permission, recommendation, nor
as an inducement to practice any patented invention without permission of the
patent owner.
TIVAR® is a registered trademark of Quadrant, Inc.
© 2007 Quadrant, Inc.
Form No T88
|